Abstract
Abstract
Laser speckle contrast Cs is a key metric for evaluating image quality in laser displays. The geometry and parameter settings of a speckle measurement system can significantly affect the measurement results. The current international standard IEC 62906-5-2:2016 and the Laser Illuminated Projector Association recommendation LIPA RP v1.0 differ in their parameter requirements, limiting the comparability of measurement results. Considering the practical operating luminance range of projection systems, 50–1000 cd/m2, and the approximately 1′ spatial resolution limit of the human eye, this study recommends the following principal parameters: an F/5.6 aperture corresponding to a human pupil diameter of 3.13–2.40 mm, an effective pixel size of 4.8 μm corresponding to the approximately 4.9 μm spatial integration scale of the human retina, and an exposure time of 50–200 ms. Measurements show that speckle contrast increases with F-number, rising by approximately 198% from F/2.8 to F/22, and decreases with increasing binning, screen tilt, and defocus. These trends agree with the spatial integration model Cs=C0⋅r/1+r2. Exposure time is not used as a parameter for matching human vision; instead, it is constrained by the requirements to avoid overexposure and maintain an adequate signal-to-noise ratio. An exposure time of 100 ms is recommended, and the actual value should be reported. Screen tilt should be avoided, and the system should preferably provide focusing assistance.
Direct answer
What can I do from this paper page?
Use this page to scan "Title Requirements and Parameter Settings of a Speckle Contrast Measurement System" quickly: start with the summary and abstract, then check the authors, source, topics, and related papers. From here, open Scollr to follow Optical Systems and Laser Technology research, save the paper, or map adjacent work.
Research areas
Follow related topics
Citation
BibTeX
@article{Liu2026Title,
title = {Title Requirements and Parameter Settings of a Speckle Contrast Measurement System},
author = {Hong Liu and 王子宁 Wang Zining and Weisheng Wang},
journal = {Electronics},
year = {2026},
doi = {10.3390/electronics15225281},
url = {https://doi.org/10.3390/electronics15225281}
}
FAQ
Using this paper in a discovery workflow
How do I find related work for this paper?
Use the related papers and topic links on this page as starting points. In Scollr, you can also open the paper and build a literature map around its references, citing papers, and related work.
How can I keep up with new Optical Systems and Laser Technology research papers?
Follow Optical Systems and Laser Technology research in Scollr. New papers from the topic flow into a personalized feed, and you can save useful studies to revisit later.
Can I cite this paper from this page?
This page includes a static BibTeX block for Title Requirements and Parameter Settings of a Speckle Contrast Measurement System. Always verify the DOI, source, and publication details against the publisher record before submitting a manuscript.
Follow this research in Scollr
Follow the topics and authors behind this paper, save useful studies, and build a literature map when you are ready to go deeper.
Get the app