Traumatic Brain Injury and Neurovascular Disturbances Peer reviewed

Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case

Graham A. Branscom, Evan M. Ren, Michael Lemonick, Bahie Ezzat and 4 more

Journal of Neurosurgery Case Lessons | May 27, 2026

Abstract

Abstract

BACKGROUND Cranioplasty is a common procedure following decompressive craniectomy for traumatic brain injury or stroke, among other reasons, in order to repair a skull defect. Cranioplasty failure is an infrequent occurrence, but in the case of synthetic implants, it is usually caused by infection and incorrect sizing. However, trauma-induced displacement, breakage, and deformities of cranioplasty implants are less common. OBSERVATIONS The authors present a unique case of a cranioplasty failure due to displacement of a polyetheretherketone (PEEK) implant secondary to catastrophic breakage of the titanium fixation plates. The cause of displacement is unknown but is suspected to be trauma. A subsequent review of the literature contextualizes common reasons for failure among synthetic implants and suggests that fracture of synthetic implants or their fixation plates is extremely rare. LESSONS The displacement of a PEEK cranioplasty implant due to breakage of titanium fixation plates is a rare, albeit possible, complication of this neurosurgical procedure. Lifestyle modifications are paramount to reduce trauma risk and resultant cranioplasty failure. The addition of miniplates may also reduce implant displacement risk. Finally, since rates of failure differ by material, careful consideration of the type of material used for the implant should be incorporated into neurosurgical planning. https://thejns.org/doi/10.3171/CASE2694

Direct answer

What can I do from this paper page?

Use this page to scan "Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case" quickly: start with the summary and abstract, then check the authors, source, topics, and related papers. From here, open Scollr to follow Traumatic Brain Injury and Neurovascular Disturbances research, save the paper, or map adjacent work.

Authors

Researchers on this paper

Graham A. Branscom

first | Icahn School of Medicine at Mount Sinai | ORCID 0009-0000-3144-9191

Evan M. Ren

middle | Icahn School of Medicine at Mount Sinai

Michael Lemonick

middle | Icahn School of Medicine at Mount Sinai

Bahie Ezzat

middle | Icahn School of Medicine at Mount Sinai | ORCID 0000-0001-9729-9122

Ziad Rifi

middle | Icahn School of Medicine at Mount Sinai | ORCID 0000-0003-3545-796X

S Majidi

middle | Icahn School of Medicine at Mount Sinai

Christopher P. Kellner

middle | Icahn School of Medicine at Mount Sinai

Tomoyoshi Shigematsu

last | Icahn School of Medicine at Mount Sinai | ORCID 0000-0003-3463-0222

Research areas

Follow related topics

Citation

BibTeX

@article{Branscom2026Displacement,
  title = {Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case},
  author = {Graham A. Branscom and Evan M. Ren and Michael Lemonick and Bahie Ezzat and Ziad Rifi and S Majidi and Christopher P. Kellner and Tomoyoshi Shigematsu},
  journal = {Journal of Neurosurgery Case Lessons},
  year = {2026},
  doi = {10.3171/case2694},
  url = {https://doi.org/10.3171/case2694}
}

FAQ

Using this paper in a discovery workflow

How do I find related work for this paper?

Use the related papers and topic links on this page as starting points. In Scollr, you can also open the paper and build a literature map around its references, citing papers, and related work.

How can I keep up with new Traumatic Brain Injury and Neurovascular Disturbances research papers?

Follow Traumatic Brain Injury and Neurovascular Disturbances research in Scollr. New papers from the topic flow into a personalized feed, and you can save useful studies to revisit later.

Can I cite this paper from this page?

This page includes a static BibTeX block for Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case. Always verify the DOI, source, and publication details against the publisher record before submitting a manuscript.

Follow this research in Scollr