Fault Detection and Control Systems Open access Peer reviewed

Intelligent flux monitoring system using fuzzy logic: Flow-fault detection and time-to-empty validity assessment

Sivarao Subramonian, Alax Balan, K. Kadirgama, Zuhair Khalim and 6 more

Advances in Science and Technology – Research Journal | Oct 29, 2026

Abstract

Abstract

This research aims to develop an intelligent flux monitoring system using fuzzy logic to support continuous flux discharge and assess the operational validity of time-to-empty (TTE) estimation during abnormal flow conditions.The problem addressed is the reduced reliability of conventional physics-based TTE estimation when the monitored system operates under faulty conditions, including supply-tube blockage, nozzle error and unstable flow.The study proposes a hybrid fuzzy-deterministic framework in which fuzzy logic functions as a diagnostic layer that complements the conventional mass-flow relationship.The framework uses flux tank weight and flux flow rate as measured inputs, whereas supply-tube-blockage and nozzle-error indicators are treated only as external reference labels for validation.The experimental record contains 500 observations sampled at 60-s intervals over 8 h 19 min, comprising 454 normal observations, 30 supply-tube-blockage observations and 16 nozzle-error observations.The Mamdani fuzzy inference system uses explicitly defined membership functions, a 16-rule base, minimum AND/implication, maximum aggregation and centroid defuzzification.All labelled fault observations have zero recorded flow, whereas normal observations range from 3.652 to 6.539 g/s; consequently, the fuzzy classifier and a fixed-flow threshold both achieve 100% sample-level accuracy on the available record. Deterministic TTE is defined as 1000 W/(60 Q) min for Q>0 and is treated as invalid when the fuzzy diagnostic index indicates abnormal flow.Using an empirical within-run depletion horizon derived from the tank-weight trajectory, normal-condition deterministic TTE gives MAE = 215.48min, RMSE = 248.85min and MAPE = 86.49%.These values are within-run consistency diagnostics rather than independent predictiveaccuracy estimates because the reference is derived from the same experiment and the recorded flow channel has an unresolved scale discrepancy.The results support the use of fuzzy logic as an interpretable flow-fault and TTE-validity gate, while independent TTE accuracy, physical sensor-noise robustness, fault-type isolation and PCB-quality improvement require calibrated and repeated experiments.

Direct answer

What can I do from this paper page?

Use this page to scan "Intelligent flux monitoring system using fuzzy logic: Flow-fault detection and time-to-empty validity assessment" quickly: start with the summary and abstract, then check the authors, source, topics, and related papers. From here, open Scollr to follow Fault Detection and Control Systems research, save the paper, or map adjacent work.

Authors

Researchers on this paper

Sivarao Subramonian

first | Universiti Teknikal Malaysia Melaka | ORCID 0000-0002-5386-4377

Alax Balan

middle

K. Kadirgama

middle | Universiti Malaysia Pahang Al-Sultan Abdullah | ORCID 0000-0002-9853-2675

Zuhair Khalim

middle | Universiti Teknikal Malaysia Melaka | ORCID 0000-0003-0359-4724

Mohd Shukor Salleh

middle | Universiti Teknikal Malaysia Melaka | ORCID 0000-0003-4800-2470

Umesh Kumar Vates

middle | Amity University | ORCID 0000-0002-1614-5082

Satish Pujari

middle | ORCID 0000-0002-0300-896X

Devarajan Ramasamy

middle | ORCID 0000-0002-6830-3732

Mohd Najib Ali Mokhtar

middle

Anuar Mohamed Kassim

last | Universiti Teknikal Malaysia Melaka | ORCID 0000-0002-1905-4231

Research areas

Follow related topics

Citation

BibTeX

@article{Subramonian2026Intelligent,
  title = {Intelligent flux monitoring system using fuzzy logic: Flow-fault detection and time-to-empty validity assessment},
  author = {Sivarao Subramonian and Alax Balan and K. Kadirgama and Zuhair Khalim and Mohd Shukor Salleh and Umesh Kumar Vates and Satish Pujari and Devarajan Ramasamy and Mohd Najib Ali Mokhtar and Anuar Mohamed Kassim},
  journal = {Advances in Science and Technology – Research Journal},
  year = {2026},
  doi = {10.12913/22998624/231333},
  url = {https://doi.org/10.12913/22998624/231333}
}

FAQ

Using this paper in a discovery workflow

How do I find related work for this paper?

Use the related papers and topic links on this page as starting points. In Scollr, you can also open the paper and build a literature map around its references, citing papers, and related work.

How can I keep up with new Fault Detection and Control Systems research papers?

Follow Fault Detection and Control Systems research in Scollr. New papers from the topic flow into a personalized feed, and you can save useful studies to revisit later.

Can I cite this paper from this page?

This page includes a static BibTeX block for Intelligent flux monitoring system using fuzzy logic: Flow-fault detection and time-to-empty validity assessment. Always verify the DOI, source, and publication details against the publisher record before submitting a manuscript.

Follow this research in Scollr

Follow the topics and authors behind this paper, save useful studies, and build a literature map when you are ready to go deeper.

Get the app