Hydrogen embrittlement and corrosion behaviors in metals Open access Peer reviewed

Hollow specimen method for tensile tests in high-pressure hydrogen gas: The role of strain rate and surface quality

Tomás Freitas, Zephanja Krzysch, Florian Konert, Jonathan Nietzke and 7 more

MRS Bulletin | Oct 15, 2026

Abstract

Abstract

Abstract The hollow specimen method enables materials evaluation in high-pressure hydrogen gas, however, open questions concerning specimen geometry, manufacturing, and gas quality have prevented its standardization for hydrogen applications. This work assesses how inner-hole surface quality and strain rate govern the hydrogen-induced degradation of metastable austenitic stainless steel AISI 304. Inner holes were produced by conventional drilling and by electrical discharge machining followed by honing, and characterized by roughness, microstructure, and residual stress. Slow strain rate tensile tests were performed in 15 MPa argon and hydrogen at strain rates from 1E−2 to 1E−6 s −1 . Both production methods showed the same trends in elongation at leakage and reduction in area, with drilled specimens considerably more degraded. Degradation increased with decreasing strain rate up to a plateau at 1E−4 s −1 . Diffusion-length estimates and fractography indicate that the degradation is governed by hydrogen-assisted crack initiation at the inner surface rather than bulk hydrogen transport. Impact statement Replacing fossil fuels with hydrogen requires that the metals used in pipelines, storage vessels, and refueling systems be qualified in the gas they will carry. Such testing is currently performed in autoclaves that consume large volumes of high-pressure hydrogen, demand extensive safety infrastructure, and are available to few laboratories worldwide. The hollow specimen method removes that barrier by confining the gas inside the specimen itself, therefore reducing significantly the amount of hydrogen used. The method was standardized, resulting in the ISO 7039:2024, however three questions raised during the standardization process, concerning specimen geometry, inner-hole manufacturing, and gas quality, have kept it from being a standard tailored to hydrogen testing. This work addresses the influence of the manufacturing process on the inner-hole surface of hollow specimens and its response to hydrogen effects. Damage begins at the machined inner surface rather than building up as hydrogen works its way into the bulk. As a result, the same steel can appear highly susceptible or barely affected depending only on how that surface was produced. Inner-surface quality must therefore be specified and reported alongside hollow specimen results. This is directly relevant to the ongoing revision of the ISO 7039:2024 for hydrogen testing.

Direct answer

What can I do from this paper page?

Use this page to scan "Hollow specimen method for tensile tests in high-pressure hydrogen gas: The role of strain rate and surface quality" quickly: start with the summary and abstract, then check the authors, source, topics, and related papers. From here, open Scollr to follow Hydrogen embrittlement and corrosion behaviors in metals research, save the paper, or map adjacent work.

Authors

Researchers on this paper

Tomás Freitas

first | Federal Institute For Materials Research and Testing | ORCID 0009-0003-9219-4139

Zephanja Krzysch

middle | Federal Institute For Materials Research and Testing

Florian Konert

middle | Federal Institute For Materials Research and Testing | ORCID 0000-0003-3799-8305

Jonathan Nietzke

middle | Federal Institute For Materials Research and Testing | ORCID 0000-0002-0594-1251

Tobias Mente

middle | Federal Institute For Materials Research and Testing | ORCID 0009-0007-8325-9657

Romeo Saliwan Neumann

middle | Federal Institute For Materials Research and Testing

Gert Nolze

middle | Federal Institute For Materials Research and Testing

Arne Kromm

middle | Federal Institute For Materials Research and Testing | ORCID 0000-0003-0340-9656

Alexander Dominic Evans

middle | Federal Institute For Materials Research and Testing | ORCID 0000-0002-0365-8639

Ken Wackermann

middle | Fraunhofer Institute for Mechanics of Materials | ORCID 0000-0003-1404-3805

Oded Sobol

last | Federal Institute For Materials Research and Testing | ORCID 0000-0003-4514-6559

Research areas

Follow related topics

Citation

BibTeX

@article{Freitas2026Hollow,
  title = {Hollow specimen method for tensile tests in high-pressure hydrogen gas: The role of strain rate and surface quality},
  author = {Tomás Freitas and Zephanja Krzysch and Florian Konert and Jonathan Nietzke and Tobias Mente and Romeo Saliwan Neumann and Gert Nolze and Arne Kromm and Alexander Dominic Evans and Ken Wackermann and Oded Sobol},
  journal = {MRS Bulletin},
  year = {2026},
  doi = {10.1557/s43577-026-01216-6},
  url = {https://doi.org/10.1557/s43577-026-01216-6}
}

FAQ

Using this paper in a discovery workflow

How do I find related work for this paper?

Use the related papers and topic links on this page as starting points. In Scollr, you can also open the paper and build a literature map around its references, citing papers, and related work.

How can I keep up with new Hydrogen embrittlement and corrosion behaviors in metals research papers?

Follow Hydrogen embrittlement and corrosion behaviors in metals research in Scollr. New papers from the topic flow into a personalized feed, and you can save useful studies to revisit later.

Can I cite this paper from this page?

This page includes a static BibTeX block for Hollow specimen method for tensile tests in high-pressure hydrogen gas: The role of strain rate and surface quality. Always verify the DOI, source, and publication details against the publisher record before submitting a manuscript.

Follow this research in Scollr

Follow the topics and authors behind this paper, save useful studies, and build a literature map when you are ready to go deeper.